41
10:GET8
Takes eight status bits that are grouped
together from the 4734s memory and
place them on top of the stack.
NOTE This group of eight bits consti-
tutes a single item on the stack.
$@0000
The address of the
group of eight status
bits in the 4734s mem-
ory.
11:GETC
Takes a constant number and places it on
top of the stack.
VALUE:0
Value of the constant
(0-255) to get.
12:PUT1
Retrieves a single status bit from the top
of the stack
and
transfers it to a single bit position on an
output port or memory location.
$@0000
8-bit output address to
which the bit is to be
transferred.
BIT #(0-7):0.
Specific location to put
the single bit into.
13:PUT8
Retrieves eight status bits that are
grouped together from the top of the stack
and transfers them to an 8-bit position on
an output port or memory location.
$@0000
8-bit output address to
which the eight bits are
to be transferred.
14:EQU0
True/False if result is zero (conserves
statements for common operation).
Next statement in
program.
None
15:DCNT
Down Count, value-1 if value > 0 (useful
for timers).
Next statement in
program.
None
16:Greater
than
True/false result of comparison (Y > X).
Next statement in
program.
None
17:Less than True/false result of comparison (Y < X).
Next statement in
program.
None
18:2BIN
Converts number from BCD (binary coded
decimal) to binary. (Use to convert TSEC,
TMIN, THR, MONTH, MDAY to binary
number before comparison.)
Next statement in
program.
None
19:2BCD Converts binary number to BCD.
Next statement in
program.
None
20:Multiply, *,
MUL
Multiplies two number.
Next statement in
program.
None
21:2BIT Converts number (0-7) to bit in byte.
Next statement in
program.
None
0:END
Always the last statement in the program.
If an END statement is inserted, it
becomes the new end of the program.
END None
Table 14: Programmable I/O Statement Operations
Operation What It Does
Screen Prompt
That Follows
Additional Information